Do a good job in the maintenance of blood cell analyzer. You need to pay attention to these!

Do a good job in the maintenance of blood cell analyzer. You need to pay attention to these!

(Summary description)Is the blood cell analyzer always blocked? Incorrect blood cell analyzer test results? Blood cell analyzer failure? I believe many laboratory doctors have encountered these situations when operating the blood cell analyzer, but at the same time, they are also very confused. Why do they encounter such a situation when they have done daily equipment maintenance. This is because many inspection physicians do not pay attention to the following details during equipment maintenance:

Do a good job in the maintenance of blood cell analyzer. You need to pay attention to these!

(Summary description)Is the blood cell analyzer always blocked? Incorrect blood cell analyzer test results? Blood cell analyzer failure? I believe many laboratory doctors have encountered these situations when operating the blood cell analyzer, but at the same time, they are also very confused. Why do they encounter such a situation when they have done daily equipment maintenance. This is because many inspection physicians do not pay attention to the following details during equipment maintenance:

Information

Is the blood cell analyzer always blocked? Incorrect blood cell analyzer test results? Blood cell analyzer failure? I believe many laboratory doctors have encountered these situations when operating the blood cell analyzer, but at the same time, they are also very confused. Why do they encounter such a situation when they have done daily equipment maintenance. This is because many inspection physicians do not pay attention to the following details during equipment maintenance:
1、 Cleaning of the bottom of the swab
Fault prone: PLT index error
Cause analysis: the bottom of the swab is often in contact with the test tube, and blood clots will form over time. If these clots fall into the leukocyte counting pool, the effect is not great. However, once it falls into the red blood cell counting pool, because there is no dissolving agent, the PLT index will jump. That is, the platelets in the sample were only about 20, and suddenly jumped to hundreds and thousands.
2、 Maintenance of probe cleaning solution
Prone to failure: probe liquid blocking hole
Cause analysis: our matched probe cleaning solution contains enzymes, which is very important for protein cleaning. However, many teachers will use 84 instead. Here is a reminder not to use 84. On the one hand, the strength is not enough, and on the other hand, there are impurities. It will not only fail to maintain the probe fluid, but will cause further hole plugging!
3: Correction of sampling needle position
Prone to failure: error in counting result
Cause analysis: during daily use, the position of the sampling needle will inevitably shift, but the relative position of the sampling needle and the swab is an important factor affecting the counting results. Therefore, it is recommended that teachers use the sampling needle height setter to correct the position of the sampling needle at least once a month.
4: Application of motor lubricating oil
Prone to failure: slow operation / burnout
Cause analysis: if the machine runs for a long time and does not give some oil to eat, the aging speed is naturally accelerated! In addition, some teachers will ask whether edible oil and sewing oil can be used. Here we should remind you that it is best to use special oil for motor. On the one hand, it is durable and heat-resistant, high efficiency and good effect. On the other hand, these mismatched oils generate heat by friction during motor operation, and it is easy to burn. This is not worth the loss!
5: Cleaning before shutdown
Prone to failure: sample probe hole plugging / crystallization in counting cell, etc.
Cause analysis: every time we finish the test, there will be more or less samples and reagent residues on the instrument. If they are not disposed of in time, on the one hand, the hole will be blocked after a long time, and on the other hand, the next test will cause technical errors and affect the final test results. So, after the last sample is tested, don't shut down the machine immediately!

Related news

China

China will become a global medical device manufacturing center, and the process of "import substitution" of domestic devices will be accelerated

On September 1, the reporter learned at the 2017 China Medical Device Industry Development Forum, the pre forum of the 2017 (34th) national pharmaceutical industry information annual conference, that the state will continue to increase investment and support for the medical device industry during the 13th Five Year Plan period
2021-02-02
At

At the end of the year, thanks to everyone who helped me all the way - from Xinke

Thank everyone who helped me all the way
2021-02-02
Instrument

Instrument maintenance and cleaning method

In use, it will be stained with dirt such as greasy, glue and sweat, and rust and mildew will occur when it is stored carelessly. These dirt will have an extremely adverse impact on the service life and performance of the instrument. The purpose of cleaning is to remove the dirt on the instrument.
2021-02-02
1

1 billion people! Evaluation and detection of the effect of Mairui targeting Xinguan vaccine after vaccination

In COVID-19, MINDRAY, which relies on respirator and other life information and supporting products in the field, has finally launched the test reagent.
2021-02-02
xinke

Established in 2004, Zhejiang Xinke Medical Technology Co., Ltd. (Jinhua Xinke Medical Instrument Co., Ltd )is a manufacturer of IVD reagents for many famous brand analyzers ,Such as Sysmex ,Abbott,Beckman ,Mindray etc .  Our main products including hematology reagents ,biochermistry reagents ,ISE solution etc .

 

CONTACT US

Add: No.133 ,Lengshui Road,Jinpan Development Zone,Jinhua City, Zhejiang Province, China 

Email:xinkebio@188.com

Fax:0579-82235397

Copyright © Zhejiang Xinke Medical Technology Co., Ltd.